One that will keep your reputation watertight for the long term.
Reality Check: Independent ‘field’ tests prove DuPont™ Tyvek® maintains vital watertightness after ageing, where many alternative underlays fail
Concerned by multiple reports of some alternative vapour-open underlays failing in their secondary water shedding role, DuPont™ Tyvek® instigated a thorough investigation into ‘real world’ performance. When the reputation of a whole class of roofing underlays is at risk because of water tightness failure in some products unable to withstand heat or UV stress, it’s time for the market leader to address the issue.
Independent expert Martin Peifer of German consultants Steildach-Technik opened up 30 roofs to take away underlay samples which the Kiwa GmbH TBU laboratory then tested in ways that exceed the limitations of current water tightness pass/fail classifications.
Standards lag behind
As building and industry codes have been working hard to catch up with a rapidly evolving market, assessment methods such as those within standard EN13859-1&2, still lag behind in evaluating vital issues such as actual longevity. Qualities such as long term waterhold – which most crucially affects the homeowner – must be assessed after exposure to natural environmental stresses, both during the build and when occupied.
Increasingly vapour-open but decreasingly fail-safe?
While ageing of underlays can positively affect vapour diffusion with increased porosity, this may adversely affect the water shedding function, should the primary covering fail. This unfortunate occurrence is becoming more prevalent in today’s increasingly stormier weather. Ultimately, the primary quality in terms of longevity is water tightness – an area which presents the most risk for property, insurance, and reputations.
Test methods:
First
the basic EN13859-1&2 W1 classification system for watertightness
was used: each specimen was exposed to a 20cm water column for 2
hours to measure not only whether any leakage occurred, but how much,
over what surface area and how quickly. In parallel a graded system
over a scale of 10 (1 being the worst performance, 10 the best) was
appplied to differentate between the failing specimens.(see pictures)
The EN20811 method for evaluating resistance to water penetration in
textiles was also used. This established, in crucial and revealing
detail, precisely how well each underlay withstood water after 5 to
10 years in a roof, or, in the case of Tyvek®, for more than 20
years. (For more detail on the test methods and results please see
this link: www.tyvek.co.uk/rooftest
Results:
The table shows the W1 results, W1 with the added grading system applied to all 17 Tyvek® roofing underlays and all 13 alternatives, as well as the EN20811 water column test results (green equals functional, red equals non-functional.)
As there is no clear definition in standards or codes, careful consideration as to how to assess functionality using this combined testing system is required. For example, with a W1-Grade 9 it is possible that a few drops of water could potentially move from the cold side to the insulation level. However, as diffusion takes place over the entire surface of the underlay, such minimal moisture will dry out rapidly and no reduction of functionality is likely. Also, the reduced pressure of free-running water in normal conditions should be taken into account.
By applying this consideration to the W1-grading scale, it is only at Grade 5 or lower that a high risk of water infiltration becomes a concern, to the point where it may get beyond control. Martin Peifer, the independent expert, thus set the W1-grade of 6 as being the acceptable limit to ensure functionality, anything less becoming critical. For EN 20811 he set the functionality limit to < 50 cm.
Bearing this in mind, the picture is as follows:
16 out of 17 Tyvek® roofing underlays can be declared functionally watertight after more than 20 years
0 out of 6 multi-layer microporous film based roofing underlays can be declared functional after less than 10 years
4 out of 7 coated roofing underlays can be declared functional after less than 10 years
Even without taking into account the age differences (the Tyvek® samples being significantly older than the other installed products), Tyvek® clearly emerges as the most reliable in terms of crucial watertightness, while there is significant cause for concern with alternative roofing underlays.
For more information about DuPont™ Tyvek® in the UK please visit: http://www.construction.tyvek.co.uk or call 01275 337660 (087 922 2740 in ROI)